STULZ – your partner for integrated liquid cooling infrastructures
“As your cooling solutions partner, we’re here to support you in navigating the complexities that arise when introducing liquids into data centers. Whether you’re building liquid-cooled data centers or integrating liquid cooling into existing air-cooled infrastructure, we’re ready to provide the answers and guidance you need.”
Valeria Mercante, Team Lead Liquid Cooling Solutions, Global Product Management
Liquid cooling technologies
-
Central to this technology is the strategic placement of cold plates directly above heat sources, particularly the processors in server units. This close proximity ensures rapid and precise heat transfer, thereby optimizing cooling efficiency. The cooling process is facilitated by a networks of small tubes that guide a liquid coolant directly to the processors. Once absorbed by the liquid coolant, the heat is swiftly carried away and circulated through coolant distribution units to a re-cooler. Here, the heat is released into the surrounding environment, completing the cooling cycle. While liquid cooling serves as the foundation of the system, a complementary air-cooling component remains essential. Approximately 20-30% of the cooling requirement is fulfilled through air-cooling mechanisms, ensuring comprehensive thermal management.
-
By isolating the Technology Cooling System (TCS) and Facilities Water System (FWS), the risk of cross-contamination and leaks is significantly reduced, thereby enhancing the overall reliability of the cooling system.
-
-
Immersion Cooling entails submerging IT equipment, such as servers, entirely into a non-conductive liquid. Typically, this liquid is contained within an insulated tank, ensuring efficient heat dissipation. Heat generated by the submerged equipment is absorbed by the liquid. To maintain optimal operating temperatures, the heated liquid is then cooled using either an external or internal heat exchanger, which is in turn connected to a re-cooler. Even with this technology, a supplementary air cooling component remains indispensable. Approximately 5% of the heat load are covered by air-cooled systems.
-
By isolating the Technology Cooling System (TCS) and Facilities Water System (FWS), the risk of cross-contamination and leaks is significantly reduced, thereby enhancing the overall reliability of the cooling system.
-
-
From design and independent product consulting to installation and maintenance, STULZ offers all services and products from a single source:
- Integrated liquid cooling systems, manufactured and tested
- Individual climate units to complement your existing liquid cooling infrastructure
Close to you around the world
With 23 subsidiaries comprising 11 production sites and 12 sales companies in Africa, America, Asia, Europe and Oceania, the company is at your side at all times. In addition, STULZ has exclusive agreements with numerous sales and service partners on all continents and is therefore represented in over 150 countries around the globe. With this global network of partners and independent manufacturers for direct chip and immersion cooling, STULZ is the right partner for all liquid cooling requirements.
Solutions from a single source
As a company with subsidiaries and partners around the globe, we have specialized in the field of mission-critical cooling technology for over 50 years. Our portfolio ranges from classic air-conditioning systems, chiller units and air handlers to Liquid Cooling solutions and humidification systems, micro data centers, services, and a proprietary monitoring software. We offer you all the cooling technology you need in the extremely dynamic world of information technology – from consulting and planning through to manufacturing and installation.
Customized to your individual needs
You have the challenge, we have the solution. The requirements for Liquid Cooling systems vary enormously depending on location, hydraulic conditions, infrastructure, and protection, not to mention reliability. STULZ offers solutions for your individual requirements – our teams will work with you to plan and implement your application.